Instruction Manual &
Safety Warnings
Table of Contents
Important Safety Warnings and
Instructions
Electrical precautions 1
Battery preparation 1
Battery precautions 1
Introduction
Items included in system 2
Additional items needed 2
System specifications 2
Installing the Pipe and Pump 3
Battery Instructions 4,5
System Connections
Connecting the backup pump 5
Installing the battery fluid sensor 5
Connecting the battery 6
Connecting the primary pump 6
Product Operation
Float switches 7
Controllers 7
1/8” weep holes 7
Understanding the Warning
Lights and Alarms
Silencing the alarm during
an emergency 7
Battery fluid low 7,8
Battery corroded or defective 8
Cleaning battery terminals 8
Replacing the battery 9
Not receiving AC power 10
Fuse alarm 10
Backup pump activated 10
Replacing the backup pump 11
Replacing the primary pump 12
Battery power level 13
Remote alarm 13
Testing the System
Testing the backup float switch 13
Testing the primary float switch 14
Maintenance Check List 14
Parts & Service Information
Technical support 14
Replacement Parts Diagram & List 15
Troubleshooting Guide 16
Warranty 17
Pro Series C33
Combination Primary and
Backup Sump Pump System
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1 - Pro Series C33

Instruction Manual &Safety WarningsTable of ContentsImportant Safety Warnings andInstructionsElectrical precautions 1Battery preparation 1Battery

Page 2 - Warnings & Instructions

brush or sandpaper. DO NOT apply corrosionresisting sprays or pads to the terminal ringsor posts after you have cleaned them, sincethis could prevent

Page 3 - System Specifications

Page 109. Plug the power cord back into the wall outlet.(You should provide additional protection forthe control unit by using a surge protector.)10.

Page 4 - Installing the Pipe and Pump

Page 11REPLACING THE BACKUP PUMPBefore you begin this process, you will need anew backup pump, new check valves, and newwire ties. The check valves ha

Page 5 - Battery Instructions

19. Connect the backup pump to the back of thegray control unit.20. Insert the fluid sensor into the top of thebattery, or into the battery cap, depen

Page 6 - System Connections

need to thread the old screws through thefoot, the strainer and into the pump.12. Line up the discharge pipes parallel to eachother and start with the

Page 7 - NEGATIVE

pump. This is normal. The hole is needed toprevent an air lock within the system. DO NOTobstruct this hole or an air lock may prevent thepump from act

Page 8 - Understanding the Warnings

Page 15ControllerDual FloatConsider a Pro Series Battery Backup Sump Pump SystemGlentronics, Inc. 800.991.0466 www.stopflooding.comModel No. DFC

Page 9 - TERMINALS AND CABLES

Page 16Pump is not plugged in . . . . . . . . . . . . . . . . . . . .No AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . .Poor power sou

Page 10 - REPLACING THE BATTERY

Page 17Limited WarrantyGLENTRONICS, INC. warrants to the original retail purchaser that all of its pump, switch, sensor, battery box and control unitp

Page 11

© 2010, Glentronics, Inc. 1806065 (07/10)Page 18CHECK OUT THIS OTHER PHCC PRO SERIES PRODUCTWATER ALARMMinimize the risk of water damageYou can detect

Page 12 - REPLACING THE BACKUP PUMP

Important SafetyWarnings & InstructionsSAVE THESE INSTRUCTIONS. This manualcontains important SAFETY WARNINGS andOPERATING INSTRUCTIONS for the Pr

Page 13 - REPLACING THE PRIMARY PUMP

IntroductionThe Pro Series Pair of Pumps combination systemis designed to provide both primary and backuppumping capabilities. The primary pump willop

Page 14 - BACKUP PUMP

Installing the Pipe and PumpThe Pro Series Pair of Pumps combination systemis compact and will fit in a sump pit as small as12” wide. It measures 23¾”

Page 15 - MAINTENANCE CHECK LIST

Battery InstructionsA new Pro Series B-2200 Standby Battery will runthis system for a minimum of 8 hours.To increase the running time of this system t

Page 16 - SIDE VIEW

Page 5switch on the front of the controller panel to thetype of battery being used with the system.System ConnectionsRisk of electrical shock or batte

Page 17

2. Installing the battery fluid sensor: Removethe cover of the battery box by pushing in thetabs on the front and back, then lifting up.Fan the area a

Page 18 - Limited Warranty

Page 7Product OperationThe dual float switch on the primary pumpcontains two large floating rings enclosed withina protective cage. Water will lift th

Page 19 - WATER ALARM

Page 8which battery you own. Be sure the fluidsensor is positioned in the second cell fromthe positive post. The hole is marked with anarrow. Replace

Comments to this Manuals

No comments