pump. This is normal. The hole is needed to
prevent an air lock within the system. DO NOT
obstruct this hole or an air lock may prevent the
pump from activating, and the basement will flood.
BE SURE TO PLUG IN THE MAIN AC PUMP WHEN
YOU HAVE COMPLETED THE TEST.
TESTING THE FLOAT SWITCH FOR THE
PRIMARY PUMP
Lift the float up with a pencil, or another non-
metallic item, and let it go to activate the pump.
The pump will run of an additional 10 seconds
after the float returns to the original position.
It will not damage the pump to run it for this
short time if the sump pit is dry. However, DO
NOT hold the float up for an extended time
without water in the sump pit.
While the pumps are active, water will come out
of the 1/8” hole that is drilled in the pipe above
the pump. This is normal. The hole is needed to
prevent an air lock within the system. DO NOT
obstruct this hole or an air lock may prevent the
pump from activating, and the basement will
flood.
MAINTENANCE CHECK LIST
Maintenance should be performed 1-2 times per
year
1. Lift the float switches on both pumps as
described above.
2. Remove all debris from the bottom of the pit.
3. Remove all debris floating in the water.
4. Remove all debris from the float switch cage.
5. Fill the pit with water. Make sure the pumps
turn on at the intended levels.
6. While the pump is running, make sure the
pump is evacuating water at a good pace and
water is coming out of the 1/8” air bleed
hole.
7. Remove the fluid sensor and yellow cap from
the battery and rinse any residue buildup from
the bottom of the battery cap. Replace the
cap and fluid sensor.
8. Check battery fluid levels.
PARTS & SERVICE INFORMATION
You can receive technical support, parts, or
service information by calling Glentronics, Inc.
at 800-991-0466, option #3, or by visiting the
Pro Series website at www.stopflooding.com.
Send your unit to the following address if repairs
are needed:
Glentronics, Inc.
640 Heathrow Drive
Lincolnshire, IL 60069-4205
Page 14